Résumés
Abstract
In order to evaluate the efficiency and to monitor the treatment of organic micropollution by advanced oxidation processes, we have developed a new detection method based on the use of an electrochemical sensor for alkylphenol detection in water. This sensor, integrating a three-electrode cell configuration, is a commercial screen-printed electrode (SPE-110GPH) that can be used for alkylphenol detection continuously by mean of a derived flow cell. The working electrode is modified by a graphene layer that enhances the sensor sensibility. The experimental conditions were optimized for the sensor incorporated into the flow cell. Linearity ranges, repeatability and accuracy were studied as well as the detection limits for each alkylphenol. The lowest detection limit was obtained with bisphenol A (60 nM) and the measurement ranges achievable with the SPE-110GPH electrode allow the continuous monitoring of treatment processes.
Keywords:
- Water treatment,
- Alkylphenol detection,
- Electrochemical sensor,
- Screen-printed electrode
Résumé
Dans le cadre de l’évaluation de l’efficacité et du suivi du traitement de la micropollution organique, par procédés d’oxydation avancée, nous avons développé une nouvelle méthode de détection qui repose sur l’utilisation d’un capteur électrochimique pour la détection des alkylphénols dans les eaux. Ce capteur, qui intègre une configuration de cellule électrochimique à trois électrodes, est une électrode sérigraphiée commerciale (SPE-110GPH) utilisée pour détecter les alkylphénols en continu dans une cellule de mesure à circulation. Le fonctionnement du capteur incorporé dans cette cellule à circulation a ainsi été optimisé. Les domaines de linéarité, la répétabilité des analyses et la justesse des réponses ont été étudiés ainsi que la limite de détection. La limite de détection la plus basse a été obtenue avec le bisphénol A (60 nM) et les plages de mesure accessibles avec l’électrode SPE-110GPH permettent d’envisager le contrôle en continu des procédés de traitement.
Mots-clés :
- Traitement de l’eau,
- Détection d’alkylphénols,
- Capteur électrochimique,
- Screen-printed electrode
Parties annexes
References
- COLIN, R. (2009). Les perturbateurs endicriniens dans l’eau. L’eau, L’industrie, Les nuisances, 319, 63-67.
- KOTULA-BALAK, M., E. POCHEC, A. HEJMEJ, M. DUDA and B. BILINSKA (2011). Octylphenol affects morphology and steroidogenesis in mouse tumor Leydig cells. Toxicol. In Vitro, 25,1018-1026.
- LUNDANES, E., T. GREIBROKK and A.M. KVISTAD (1998). Determination of alkylphenols in water samples by solid-phase extraction on to poly(styrene-divinylbenzene) and quantification by liquid chromatography with UV-detection. Chromatographia, 48, 707–713.
- MINISTÈRE DU DÉVELOPPEMENT DURABLE, DE L’ENVIRONNEMENT ET DES PARCS DE QUÉBEC. CENTRE D’EXPERTISE EN ANALYSE ENVRONNEMENTALE DU QUÉBEC (2012). Détermination des alkylphénols dans les eaux usées: extraction liquide-solide, dérivation et dosage par chromatographie en phase gazeuse couplée à un spectromètre de masse, MA. 404 – Alkylphénols 1.0, 14 p.
- ROGERS, J.A., L. METZ and V.W. YONG (2013). Review: Endocrine disrupting chemicals and immune responses: a focus on bisphenol-A and its potential mechanisms. Mol. Immunol., 53, 421–430.
- RYKOWSKA, I. and W. WASIAK (2006). Properties, threats, and methods of analysis of Bisphenol A and its derivatives. Acta Chromatogr., 16, 1–21.
- ZHENG, Q., P. YANG, H. XU, J. LIU AND L. JIN (2012). A simple and sensitive method for the determination of 4-n-octylphenol based on multi-walled carbon nanotubes modified glassy carbon electrode. J. Environ. Sci., 24, 1717–1722.
- ZHOU, W.-S., B. ZHAO, X.-H. HUANG and X.-D. YANG (2013). Electrochemical determination of 4-nonylphenol on graphene-chitosan modified glassy carbon electrode. Chinese J. Anal. Chem., 41, 675–680.